Volume 5 Issue 5
Nov.  2016
Turn off MathJax
Article Contents
Hu Cheng, Liao Xin, Xiang Yin, Zeng Tao. Novel Analytic Method for Determining Micro-Doppler Measurement Sensitivity in Life-detection Radar[J]. Journal of Radars, 2016, 5(5): 455-461. doi: 10.12000/JR16090
Citation: Hu Cheng, Liao Xin, Xiang Yin, Zeng Tao. Novel Analytic Method for Determining Micro-Doppler Measurement Sensitivity in Life-detection Radar[J]. Journal of Radars, 2016, 5(5): 455-461. doi: 10.12000/JR16090

Novel Analytic Method for Determining Micro-Doppler Measurement Sensitivity in Life-detection Radar

DOI: 10.12000/JR16090
Funds:

The National Natural Science Foundation of China (61120106004, 61225005), The 111 Project of China (B14010)

  • Received Date: 2016-08-17
  • Rev Recd Date: 2016-10-18
  • Publish Date: 2016-10-28
  • In recent years, a new non-contact life detecting device has been developed, known as life-detection radar, which can measure bodily movement and locate human subjects. Typically, the amplitude of the vibration being measured is quite small, so the measurement is easily contaminated by noise in the radar system. To date, there is no effective index for judging the influence of noise on the vibration measurements in this radar system. To solve this problem, in this paper, we define the micro-Doppler measurement sensitivity to analyze the influence of noise on the measurement. We then perform a simulation to generate a performance curve for the radar system.

     

  • loading
  • [1]
    路国华. 生物雷达目标信息识别技术的实验研究[D].[博士论文], 第四军医大学, 2005. Lu Guohua. Experimental study on the technology of recognizing thetarget information based on bioradar[D].[Ph.D. dissertation], Fourth Military Medical University, 2005.
    [2]
    Skolnik M I. Introduction to Radar System-2nd edition[M]. New York:McGraw Hill, 1980.
    [3]
    张杨, 王健琪, 荆西京, 等. 基于自适应滤波的生物雷达干扰抑制方法[J]. 仪器仪表学报, 2009, 30(4):807-811. Zhang Yang, Wang Jianqi, Jing Xijing, et al.. Study on interference restraining of bioradar through adaptive filtering[J]. Chinese Journal of Scientific Instrument, 2009, 30(4):807-811.
    [4]
    Iii E F G. Radar flashlight for through-the-wall detection of humans[J]. Proceedings of SPIE-The International Society for Optical Engineering, 1998, 3375:280-285.
    [5]
    罗漫江. 生命探测仪的技术研究[D].[硕士论文], 西安电子科技大学, 2004. Luo Manjiang. Research on technologies of radar body-detect system[D].[Master dissertation], Xidian University, 2004.
    [6]
    Partida, Almorox, Mateo, et al.. Through-the-wall surveillance with millimeter-wave LFMCW radars[J]. IEEE Transactions on Geoscience and Remote Sensing, 2009, 47(6):1796-1805.
    [7]
    He F, Zhu G F, Huang X T, et al.. Preliminary results of ultra-wideband through-the-wall life-detecting radar[C]. IEEE National Radar Conference, Washington, DC, 2010:1327-1330.
    [8]
    Kiriazi J E, Boric-Lubecke O, and Lubecke V M. Dual-frequency technique for assessment of cardiopulmonary effective RCS and displacement[J]. IEEE Sensors Journal, 2012, 12(3):574-582.
    [9]
    Bloice J A and Caro C G. Contactless apnoea detector using low energy radar[J]. Journal of Physiology, 1972, 223(1):3-4.
    [10]
    张翼, 邱兆坤, 朱玉鹏. 基于微多普勒信息的人体步态参数估计[J]. 信号处理, 2010, 26(6):917-922. Zhang Yi, Qiu Zhaokun, and Zhu Yupeng. Human Gait parameter estimation based on micro Doppler feature[J]. Signal Processing, 2010, 26(6):917-922.
    [11]
    吴世有, 黄琼, 陈洁, 等. 基于超宽带穿墙雷达的目标定位识别算法[J]. 电子与信息学报, 2010, 32(11):2624-2629. Wu Shiyou, Huang Qiong, Chen Jie, et al.. Target localization and identification algorithm for ultra wideband through-wall radar[J]. Journal of Electronics & Information Technology, 2010, 32(11):2624-2629.
    [12]
    Wang J Q, Zheng C X, Jin X J, et al.. Study on a non-contact life parameter detection system using millimeter wave[J]. Space Medicine & Medical Engineering, 2004, 17(3):157-61.
    [13]
    Franks C I, Watson J B, Brown B H, et al.. Respiratory patterns and risk of sudden unexpected death in infancy[J]. Archives of Disease in Childhood, 1980, 55(8):595-599.
    [14]
    Agrawal A, Fougere B, Oravakandy M, et al.. Design, construction and testing of a microwave radar system for through-wall surveillance[D]. University of Manitoba, Canada, 2004.
    [15]
    Droitcour A D, Boric-Lubecke O, Lubecke V M, et al.. Range correlation and I/Q performance benefits in single-chip silicon Doppler radars for noncontact cardiopulmonary monitoring[J]. IEEE Transactions on Microwave Theory and Techniques, 2004, 52(3):838-848.
    [16]
    Skolnik M I. RADAR Handbook-2nd edition[M]. New York:McGraw Hill, 1990.
  • 加载中

Catalog

    通讯作者: 陈斌, bchen63@163.com
    • 1. 

      沈阳化工大学材料科学与工程学院 沈阳 110142

    1. 本站搜索
    2. 百度学术搜索
    3. 万方数据库搜索
    4. CNKI搜索
    Article views(3292) PDF downloads(1490) Cited by()
    Proportional views
    Related

    /

    DownLoad:  Full-Size Img  PowerPoint